Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Analog Voltage and Pulse Train Reference User Manual

Page 422

Advertising
background image

11 Appendix

11.2.2 Parameters

11-34

∗1. Normally set to "0." When using an external regenerative resistor, set the capacity (W) of the regenerative resistor

unit.

∗2. The upper limit is the maximum output capacity (W) of the SERVOPACK.

∗3. These parameters can be set in SERVOPACKs with safety modules. For details, refer to

Σ

-V Series User’s Manual,

Safety Module (No.: SIEP C720829 06).

Pn551

2

Analog Monitor 2 Offset Voltage

-10000 to

10000

0.1 V

0

Immediately

Setup

6.1.3

Pn552

2

Analog Monitor
Magnification (

×1)

-10000 to

10000

×0.01

100

Immediately

Setup

6.1.3

Pn553

2

Analog Monitor
Magnification (

×2)

-10000 to

10000

×0.01

100

Immediately

Setup

6.1.3

Pn560

2

Remained Vibration

Detection Width

1 to 3000

0.1%

400

Immediately

Setup

6.7.1

Pn561

2

Overshoot Detection Level

0 to 100

1%

100

Immediately

Setup

6.3.1
6.4.1

Pn600

2

Regenerative Resistor Capacity

∗1

Depends on

SERVOPACK

Capacity

∗2

10 W

0

Immediately

Setup

3.7.3

Pn601

2

Dynamic brake resistor capacity

0 or higher

(Max. value

depends on

model.)

∗2

10 W

0

Immediately

Setup

3.8.2

Pn621 to
Pn628

*3

SERVOPACK: Safety Module
Parameters

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When Enabled Classifi-

cation

Reference

Section