11.1 Connection to Host Controller

11-5

11

Ap

pend

ix

11.1.4 Connection to OMRON’s Position Control Unit

∗1. The ALM signal is output for about five seconds after the control power is turned ON. Take this into consideration

when designing the power ON sequence. Also, use the ALM signal to actuate the alarm detection relay 1Ry to stop
the main circuit power supply to the SERVOPACK and converter.

∗2. Set parameter Pn200.0 to "1."

∗3. Connect the shielded wire to the connector shell.

∗4.

represents twisted-pair wires.

Note 1. Only the signals related to the SERVOPACK and the OMRON Position Control Unit are shown in the diagram.

2. The main circuit power supply is a three-phase 200-VAC SERVOPACK input in the example.
3. Incorrect signal connections will damage the Position Control Unit, SERVOPACK, or converter. Wire all con-

nections carefully.

4. Open the signal lines not to be used.
5. The above connection diagram shows only X-axis connections. When using other axes, make connections to the

SERVOPACK in the same way.

6. Short-circuit the normally closed (NC) input terminals that are not used at the I/O connector section of the posi-

tion control unit.

7. Make the settings so that the servomotor can be turned ON/OFF by the Servo ON (/S-ON) signal.
8. The SERVOPACK incorporates safety functions to protect people from the hazardous operation of the movable

parts of the machines, reduce the risk, and ensure the safety of the machine in operation. Necessary circuits and
settings are required in CN8 to use these functions. If these functions are not used, use the SERVOPACK with the
enclosed safety jumper connected to CN8. For details, refer to 5.11 Safety Function.

Position Control Unit

manufactured by OMRON Corporation

CS1W-NC133 / 233 / 433

Servomotor

5-V power supply for pulse output

5-V GND for pulse output

24-V power supply for output

24-V GND for output

CCW(+) output

CCW(-) output

CW(+) output

CW(-) output

Origin input signal

Origin input common

Error counter reset output

X-axis CW limit input

X-axis CCW limit input

X-axis immediate stop input

X-axis external interrupt input

X-axis origin proximity input

Connector
shell

Control
power supply

Main circuit
power supply

I/O power supply

CN2

CN1

A3

A5

A6

A7

A4

8

20
25

L3

L2

L1

19

12

7

14

15

W

V

U

A16

A11

A14

A1
A2

A8

A20

A22

A23

A21

A19

11

/SIGN

CLR

/CLR

PCO

PULS

/PULS

SIGN

/PCO

COIN+
/COIN-

A24

26

31

32

44

42
43

47
40

+24-V-IN

/S-ON

P-OT

N-OT

/ALM-RST

ALM-

ALM+

1Ry

FG

∗1

∗2

∗3

∗4

+5 V

Input common

M

ENC

+

-

+24 V

0

24

+24

V

V

SERVOPACK and converter

CN101

Analog

Advertising