10 Troubleshooting

10.1.2 Troubleshooting of Alarms

10-8

A.041:
Encoder Output Pulse

Setting Error

The encoder output pulse (Pn212)

is out of the setting range and
does not satisfy the setting condi-
tions.

Check the parameter Pn212.

Set Pn212 to a correct value.

A.042:
Parameter

Combination Error

The speed of program JOG oper-
ation (Fn004) is lower than the

setting range after having
changed the electronic gear ratio
(Pn20E/Pn210) or the servomo-

tor.

Check if the detection conditions

*1

are satisfied.

Decrease the setting of the elec-
tronic gear ratio (Pn20E/Pn210).

The speed of program JOG oper-
ation (Fn004) is lower than the
setting range after having
changed the setting of the pro-

gram JOG movement speed
(Pn533).

Check if the detection conditions

*1

are satisfied.

Increase the setting of the program
JOG movement speed (Pn533).

The moving speed of advanced
autotuning is lower than the set-
ting range after having changed
the electronic gear ratio (Pn20E/
Pn210) or the servomotor.

Check if the detection conditions

*1

are satisfied.

Decrease the setting of the elec-
tronic gear ratio (Pn20E/Pn210).

A.044:
Semi-closed/Fully-

closed Loop Control

Parameter Setting

Error

The setting of the fully-closed
module does not match with that
of Pn002.3.

Check the settings of Pn002.3.

The setting of fully-closed module
must be compatible with the setting
of Pn002.3.

A.050:
Combination Error
(The SERVOPACK and
servomotor capacities do
not correspond.)

The SERVOPACK and servomo-
tor capacities do not match each
other.

Check the capacities to see if they
satisfy the following condition:

Select the proper combination of
SERVOPACK and servomotor
capacities.

An encoder fault occurred.

Replace the servomotor and see if
the alarm occurs again.

Replace the servomotor (encoder).

A fault occurred in the SERVO-
PACK or converter.

The SERVOPACK or converter
may be faulty. Replace the SERVO-
PACK or converter.

A.051:
Unsupported Device

Alarm

An unsupported serial converter
unit, encoder, or external encoder
is connected to the SERVO-
PACK.

Check the product specifications,
and select the correct model.

Select the correct combination of
units.

A.0b0:
Cancelled Servo ON

Command Alarm

After executing the utility func-
tion to turn ON the power to the
motor, the servo ON signal (/S-

ON) was sent from the host con-
troller.

Turn the SERVOPACK power sup-
ply OFF and then ON again or exe-

cute a software reset.

∗1. Detection conditions

If one of the following conditions detected, an alarm occurs.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions

Servomotor capacity

SERVOPACK capacity ≤

4

1
4

Pn533 [min

-1

]

×

6

× 10

5

Encoder resolution

Pn20E
Pn210

Max Motor Speed [min

-1

]

×

About 3.66

× 10

12

Encoder resolution

Pn20E
Pn210