1 main circuit wiring, 1 main circuit terminals, Analog – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Analog Voltage and Pulse Train Reference User Manual

Page 51

Advertising
background image

3.1 Main Circuit Wiring

3-3

3

Wi

ring an

d Conn

ecti

on

3.1 Main Circuit Wiring

The names and specifications of the main circuit terminals are given below.

Also this section describes the general precautions for wiring and precautions under special environments.

3.1.1 Main Circuit Terminals

The names and specifications of the main circuit terminals are given below.

Note: For the purpose of this description, the SERVOPACK is shown with the front cover removed. Always keep the front

cover attached when using the SERVOPACK.

SERVOPACK

CN115

U, V, W

CN103, CN104

P, N

DU, DV, DW

Analog

SERVOPACK

Terminals

Name

Specifications

P, N

Main circuit DC voltage input termi-

nals

Connect these terminals to the P and N terminals on the converter.

U, V, W

Servomotor terminals

Connect these terminals to the Servomotor terminals.

CN103,

CN104

Control power input connectors

CN103 is the 24 VDC (

±15%) input. CN104 takes the same input,

but it is normally not necessary to connect it.

DU, DV,

DW

Dynamic brake unit terminals

Connect these terminals to the dynamic brake unit.

CN115

Dynamic brake unit connector

Connect this connector to the DBON and DB24 terminals on the

dynamic brake unit.

+, -

NC

Do not connect these terminals.

Ground terminal

Connect this terminal to the power supply ground terminal and the
Servomotor ground terminal, and then ground it.

Advertising