CPS6000 –48V Indoor/Outdoor Power Shelf


Issue 21 January 2008

167

cha cn1,dth=40

To initiate a manual boost charging, i.e., place the plant into boost charging mode, type in the
following command:

ope dc1,stt=“boost”

The tables below summarize the object-attribute pairs in the system along with the commands
that can be used with the pair and the valid range that the attribute may have. The values in
bold text are the default settings for the attributes.

Power System

Related Commands

obj,attr

description sta

cha

ope

type

range

of

values

ps1,des Power

system

description

x text “QS840A”

ps1,sid Site

ID

x x text Up to 15 characters:””

ps1,swv Software

version

x text ACU software version

ps1,ltt Lamp

test

x

number 1: do lamp test

ps1,usl

Update serial link

x

number 1:perform update serial link

ps1,amt

System ambient temperature

x

number dd°C

ps1,ptt Communication

port

type

x x text “LOCAL”, “MODEM”

ps1,dls

Daylight savings time enable

x x number 0: disable, 1: enable

ps1,tim Time

x x time hh:mm:ss (24-hour format)

ps1,dat Date

x x date dd-mm-yy

Site ID: If desired, you may type in a maximum 15 alpha-numeric character set to

uniquely define a site location.

Update Serial Link: Running this command allows the system controller to retake

inventory of using equipment. Use this command to update acknowledged equipment

when, for example, a system is to run with one less rectifier.