169

Alarm Thresholds/Relays

Related Commands

obj,attr

description sta

cha

ope

type

range

of

values

bda1,acc

Battery on discharge relay

x x

text “R1” ,“R2”, “R3”, “R4”, or “”

bda1,ast

Battery on discharge alarm state

x

number 0:not

active

1:active

bda1,sev

Battery on discharge severity

x x

text “MAJ”,“MIN” , or “RO"

bda1,thr

Battery on discharge threshold

x x

number 46-55:51V

bta1,acc

High battery temperature relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

bta1,ast

High batt temperature alarm state

x

number 0:not

active

1:active

bta1,sev

High battery temperature severity

x x

text “MAJ”,

MIN” , or “RO"

bta1,thr High

battery

temperature

x x

number 30-85:55C

hfv1,acc High

voltage

relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

hfv1,ast

High voltage alarm state

x

number 0:not

active

1:active

hfv1,bth

High boost voltage threshold

x x

number 50-60:56V

hfv1,fth

High float voltage threshold

x x

number 50-60:56V

hfv1,sev High

voltage

severity

x x

text “MAJ”,

MIN” , or “RO"

hva1,acc

Very high voltage relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

hva1,ast

Very high voltage alarm state

x

number 0:not

active

1:active

hva1,bth

Very high boost voltage threshold

x x

number 50-60:57V

hva1,fth

Very high float voltage threshold

x x

number 50-60:57V

hva1,sev

Very high voltage severity

x x

text “MAJ”, “MIN” , or “RO"

rtl1,acc

Reserve time low relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

rtl1,ast

Reserve time low alarm state

x

number 0:not

active

1:active

rtl1,sev

Reserve time low severity

x x

text “MAJ”,

MIN” , or “RO"

rtll,thr

Reserve time low threshold

x x

number 0-99.9 hours

vla1,acc

Very low voltage relay

x x

text “R1” ,“R2”, “R3”, R4, or “”

vla1,ast

Very low voltage alarm state

x

number 0:not

active

1:active

vla1,sev

Very low voltage severity

x x

text “MAJ”,“MIN” , or “RO"

vla1,thr

Very low voltage threshold

x x

number 40-51:46V

amtl1,acc Low ambient temp relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

amtl1,ast

Low ambient temp alarm state

x

number 0:not

active

1:active

amtl1,sev Low ambient temp severity

x x

text “MAJ”,

MIN” , or “RO"

amtl1,thr

Low ambient temp threshold

x x

number -40-10:-40C

amth1,acc High ambient temp relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

amth1,ast High ambient temp alarm state

x

number 0:not

active

1:active

amth1,sev High ambient temp severity

x x

text “MAJ”,

MIN” , or “RO"

amth1,thr High ambient temp threshold

x x

number 35-75:75C