Alarm Thresholds/Relays

Related Commands

obj,attr

description sta

cha

ope

type

range

of

values

acf1,acc AC

fail

relay

x x

text “R1”

,“R2”, “R3”, “R4”, or “”

acf1,ast

AC fail alarm state

x

number 0:not

active

1:active

acf1,sev

AC fail severity

x x

text “MAJ”,

MIN” , or “RO"

amj1,acc

Major auxiliary alarm relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

amj1,ast

Major auxiliary alarm state

x

number 0:not

active

1:active

amj1,sev

Major auxiliary alarm severity

x x

text “MAJ”, “MIN” , or “RO"

bbl1,acc

Clock battery low relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

bbl1,ast

Clock battery low alarm state

x

number 0:not

active

1:active

bbl1,sev

Clock battery low severity

x x

text

“MAJ”, “MIN” , or “RO"

bfa1,acc

Check battery alarm relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

bfa1,ast

Check battery alarm state

x

number 0:not

active

1:active

bfa1,sev

Check battery alarm severity

x x

text “MAJ”,

MIN” , or “RO"

bts1,acc

Battery test active relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

bts1,ast

Battery test alarm state

x

number 0:not

active

1:active

bts1,sev

Battery test active severity

x x

text

“MAJ”, “MIN” , or “RO"

cfo1,acc

Contactor 1 fail relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

cfo1,ast

Contactor 1 fail alarm state

x

number 0:not

active

1:active

cfo1,sev

Contactor 1 fail severity

x x

text “MAJ”, “MIN” , or “RO"

cfo2,acc

Contactor 2 fail relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

cfo2,ast

Contactor 2 fail alarm state

x

number 0:not

active

1:active

cfo2,sev

Contactor 2 fail severity

x x

text “MAJ”, “MIN” , or “RO"

cma1,acc Minor

communication

relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

cma1,ast Minor

communication

alarm

state

x

number 0:not

active

1:active

cma1,sev Minor

communication

severity

x x

text “MAJ”,

MIN” , or “RO"

cno1,acc

Contactor 1 open relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

cno1,ast

Contactor 1 open alarm state

x

number 0:not

active

1:active

cno1,sev

Contactor 1 open severity

x x

text “MAJ”, “MIN” , or “RO"

cno2,acc

Contactor 2 open relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

cno2,ast

Contactor 2 open alarm state

x

number 0:not

active

1:active

cno2,sev

Contactor 2 open severity

x x

text “MAJ”, “MIN” , or “RO"

cpa1,acc

Circuit pack fail relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

cpa1,ast

Circuit pack fail alarm state

x

number 0:not

active

1:active

cpa1,sev

Circuit pack fail severity

x x

text “MAJ”,

MIN” , or “RO"

faj1,acc

Major fuse alarm relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

faj1,ast

Major fuse alarm state

x

number 0:not

active

1:active

faj1,sev

Major fuse alarm severity

x x

text “MAJ”, “MIN” , or “RO"

fan1,acc

Minor fuse alarm relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

fan1,ast

Minor fuse alarm state

x

number 0:not

active

1:active

fan1,sev

Minor fuse alarm severity

x x

text “MAJ”,

MIN” , or “RO"

isd1,acc

Imminent shutdown relay

x x

text

“R1” ,“R2”, “R3”, “R4”, or “”

isd1,ast

Imminent shutdown alarm state

x

number 0:not

active

1:active

isd1,sev

Imminent shutdown severity

x x

text “MAJ”, “MIN” , or “RO"

macf1,acc Multiple AC fail relay

x x

text “R1”

,“R2”, “R3”, “R4”, or “”

macf1,ast Multiple AC fail alarm state

x

number 0:not

active

1:active