Brocade Mobility RFS7000-GR Controller System Reference Guide (Supporting software release 4.1.0.0-040GR and later) User Manual

Page 211

Advertising
background image

Brocade Mobility RFS7000-GR Controller System Reference Guide

197

53-1001944-01

Viewing Access Port Information

4

7. The Monitoring/Recovery Configuration section contains the following configuration items:

8. The Diagnostic Configuration section contains the following two configuration items:

9. The Calibration Schedule contains the following calibration settings:

10. Once the settings have been configured, click the Run Calibration button to start a Smart RF

calibration.

Assign - Tx Power

Check this box to enable automatic assignment of transmit power.

Assign - Rescuers

Check this box to enable automatic assignment of rescuers along with rescuing
power.

Available

The Available box lists all available channels for Smart RF.

Configured

The Configured box lists all channels enabled for Smart RF.

Add

To add a channel to the configured list, select one or more channels from the
Available box and click the Add button.

Remove

To remove a channel from the configured list, select one or more channels from
the Available box and click the Remove button.

Number of Rescuers

Assign a number of radios to dedicate as rescuers. The valid range is between 1
and 5.

Retry Threshold(avg
attempts/pkt)

Specify the retry threshold which is the average number of retries per packet to
cause a radio to re-run channel selection.

Hold Time(seconds)

Specify the global hold time in seconds. The valid range is between 30 and 65535
seconds.

Assignable Power
Range(dBm)

Specify a valid range for the power in dBm. The valid minimum is 4 and maximum
is 20.

Scan Dwell
Time(seconds)

Specify the RF Scan Dwell Time in seconds. The valid range is between 1 and 10
seconds.

Interference Recovery

Check this box to enable monitoring for interference and self-healing it by rescuer.

Faulty Radio Recovery

Check this box to enable monitoring for defective radio and self-healing by its
rescuer.

Coverage Hole Recovery

Check this box to enable monitoring and recovering for coverage holes.

Verbose Mode

Check this box to enable verbose diagnostic information for Smart RF.

Extensive Scan Mode

Check this box to enable extensive scan mode when using Smart RF.

Schedule Calibration

Check this box to enable scheduled RF Calibration.

Start Date

If scheduled RF Calibration is enabled, enter a start date in MM/DD/YY format for
the start date of scheduled calibration.

Start Time

If scheduled RF Calibration is enabled, enter a start time in HH:MM:SS format for
the start time of scheduled calibration.

Interval

If scheduled RF Calibration is enabled, enter an interval in days for how long the
scheduled calibration should continue after its start date.

Advertising