Publication 0160-5.5 - September 1997

C-12

ODVA Interface Parameter Descriptions

ODVA Drive Profile Interface
Parameters (Continued)

Parameter

Number

Parameter

Group

Name and Description

Object

Mapping

(Class-

Instance-

Attribute)

Min./Max.

Range

Units

Factory

Default

87

DeviceNet
Configura-
tion

[Change of State Mask]
This parameter, available with version 2.00 or later, is a 16 bit mask used
to enable automatic change of state messages. A 0 disables the indi-
cated status from causing an automatic message. A 1 enables the status.
The mask is applied to the defined input status assembly. The default
value is 0xFFFF.

0xB4-1-13

0 to
0xFFFF

Numeric
Value

0xFFFF

88

DeviceNet
Configura-
tion

[Local Return Mode]
This parameter, available with version 2.00 or later, sets the input mode
the drive will use when transitioning from network to local control. This is
only used with input mode 2. Available values are 0, 1, 3, 4, and 5.

0xB4-1-14

0 to 5

Numeric
Value

0