Configuration assembly data formats – Rockwell Automation 160 DEVICENET (DN1) MODULE FRN 1-2.XX User Manual

Page 85

Advertising
background image

Publication 0160-5.5 - September 1997

B-24

DeviceNet Information

Configuration Assembly Data
Formats

Instance 190 Data Format (Full Configuration Assembly – Series A – Signal Follower Model)

Config Num.

Parameter

Number

Description

Size

Config Num.

Parameter

Number

Description

Size

1

30

Accel Time 1

2

23

52

DB enable

1

2

31

Decel Time 1

2

24

53

S-Curve

1

3

32

Minimum Frequency

1

25

55

Memory Probe Address

2

4

33

Maximum Frequency

2

26

57

Program Lock

1

5

34

Stop Mode Select

1

27

58

Internal Frequency

2

6

35

Base Frequency

1

28

59

Frequency Select

1

7

36

Base Voltage

2

29

60

Analog Scale Teach

1

8

37

Maximum Voltage

2

30

15

Interface Select

1

9

38

Boost Select

1

31

77

Motor Base RPM

2

10

39

Skip Frequency

2

32

28

DN Fault Mode

1

11

40

Skip Frequency Band

1

33

22

Output Assembly

1

12

41

Motor Overload Select

1

34

23

Input Assembly

1

13

42

Motor Overload Current

2

35

18

Nonvolatile MAC ID

1

14

43

Current Limit

1

36

19

Nonvolatile Baud

1

15

44

DC Hold Time

1

37

24

Assembly Word 0

1

16

45

DC Hold Voltage

1

38

25

Assembly Word 1

1

17

46

Input Mode

1

39

26

Assembly Word 2

1

18

47

Output Configuration

1

40

27

Assembly Word 3

1

19

48

Output Threshold

2

41

85

DNet Idle Mode

1

20

49

PWM frequency

1

42

87

Change of State Mask

2

21

50

Restart Tries

1

43

88

Local Return Mode

1

22

51

Restart Time

2

44

20

Bus Off Error

1

!

!

!

!

ATTENTION: Changing this parameter value may cause unpredictable network conditions, resulting in equipment damage, personal injury, or death.
Ensure that you understand how changing this parameter affects your application.

Advertising