Configuration assembly data formats (continued) – Rockwell Automation 160 DEVICENET (DN1) MODULE FRN 1-2.XX User Manual

Page 88

Advertising
background image

Publication 0160-5.5 - September 1997

DeviceNet Information

B-27

Configuration Assembly Data
Formats (Continued)

Instance 190 Data Format (Full Configuration Assembly – Series B Preset Model)

Config Num.

Parameter

Number

Description

Size

Config Num.

Parameter

Number

Description

Size

1

30

Accel Time 1

2

29

61

Preset Frequency 0

2

2

31

Decel Time 1

2

30

62

Preset Frequency 1

2

3

32

Minimum Frequency

1

31

63

Preset Frequency 2

2

4

33

Maximum Frequency

2

32

64

Preset Frequency 3

2

5

34

Stop Mode Select

1

33

65

Preset Frequency 4

2

6

35

Base Frequency

1

34

66

Preset Frequency 5

2

7

36

Base Voltage

2

35

67

Preset Frequency 6

2

8

37

Maximum Voltage

2

36

68

Preset Frequency 7

2

9

38

Boost Select

1

37

69

Accel Time 2

2

10

39

Skip Frequency

2

38

70

Decel Time 2

2

11

40

Skip Frequency Band

1

39

71

IR Compensation

1

12

41

Motor Overload Select

1

40

72

Slip Compensation

1

13

42

Motor Overload Current

2

41

73

Reverse Disable

1

14

43

Current Limit

1

42

15

Interface Select

1

15

44

DC Hold Time

1

43

77

Motor Base RPM

2

16

45

DC Hold Voltage

1

44

28

DN Fault Mode

1

17

46

Input Mode

1

45

22

Output Assembly

1

18

47

Output Configuration

1

46

23

Input Assembly

1

19

48

Output Threshold

2

47

18

Nonvolatile MAC ID

1

20

49

PWM frequency

1

48

19

Nonvolatile Baud

1

21

50

Restart Tries

1

50

24

Assembly Word 0

1

22

51

Restart Time

2

51

25

Assembly Word 1

1

23

52

DB enable

1

52

26

Assembly Word 2

1

24

53

S-Curve

1

53

27

Assembly Word 3

1

25

55

Memory Probe Address

2

54

85

DNet Idle Mode

1

26

57

Program Lock

1

55

87

Change of State Mask

2

27

58

Internal Frequency

2

56

88

Local Return Mode

1

28

59

Frequency Select

1

57

20

Bus Off Error

1

!

!

!

!

ATTENTION: Changing this parameter value may cause unpredictable network conditions, resulting in equipment damage, personal injury, or death.
Ensure that you understand how changing this parameter affects your application.

Advertising