- Door Commands: Determines if and when

associated users will be able to command doors
in applicable areas through LCD-keypads or this
software.

Elevators/Lifts and Floors: This selection applies to
elevator (lift) and floor control as well (if applicable).

- Door Class A/B/C Schedule: Determines if

and when applicable users will be able to enter
at readers set to allow access for any of these
door classes during certain times.

Door class restrictions can also be customized for
individual readers. Related Topics:

"Enable Class

Checking", and "[Class Map]" in the reader
configuration section for doors and/or elevators (lifts).
Master Override: With 'Master Override' authority
(previous), these scheduled door class settings are
ignored (same as A/B/C – 'Always').
Arm/Disarm Authorities: Inability to disarm also blocks
the ability to enter an armed area. (See "

Arming

", previous.)

Elevators (Lifts): This setting pertains to elevators as
well (controlled floor access).

Floor Map

(systems with elevators and floors)

- (3D list of floors): Systems with elevator

controllers provide controlled access to system
floors. Select the floors to be allowed for
persons associated with this user-authority.
(Click the floor names, or within the 3D 'stack' of
floors.)

Floor access is also affected by:
+ Other Authority Settings: Selections under

"Access"

and

"Access Schedule"

for the

area associated with the elevator reader;

+ Area Configuration Settings: "Arm/Disarm

schedule", plus whether or not the area will "Allow
out of schedule opens";

+ Elevator/Reader Configuration Settings: "Class

Map" schedule and settings, plus misc. items such
as "Lockout".

Tip: Elevators and/or specific floors can also be set so
anyone can access during certain times regardless of
their authorities (i.e., without using an access
card/token). This can be manually via maps or "control
& status", or through a 'desecure schedule' included in
the set-up for each floor and/or elevator cab.

LCD

- LCD Name: A shorter version of the name to be

displayed at LCD keypads. This is assigned
automatically, and can also be changed if
desired (max. 12 chars., plain text).

(Ranges of Users and Authorities)

This determines the users and authorities that users
associated with this authority (being edited) will, in turn,
be able to edit through LCD keypads. This allows a
facility with multiple tenants (e.g., row of shops) to be
managed as a single account—with each tenant able to
edit their own range(s) of users and authorities.
ATTENTION: Do NOT leave these blank unless you
wish to block users associated with this authority from
editing any users and/or authorities through LCD
keypads.

- User Ranges: Up to 8 ranges of users to be

accessible/editable through system keypads (by
users associated with this specific authority
being edited).

Steps: 1) Click a range/position in the list; 2) Enter
start and end values in the boxes provided; 3) Click
[Add] or [Update] (as applicable); 4) Repeat for any
additional ranges as applicable.
Tip: If you enter adjacent ranges (e.g. 1-99 and 100-
199), they will be changed to a single range
automatically (e.g., 1-199).

- Authority Ranges: Up to 8 ranges of user

authorities to be accessible/editable through
system keypads (by users associated with this
specific authority being edited).

Steps and Notes: See the details for 'User Ranges',
previous.