Special – Interlogix VEREX Director User Manual

Page 236

Advertising
background image

228

Verex Director V4.9.1 User's Guide

21-0381E v4.9.1

'checksum' (1-40);

- Start: The starting position of the data being

checked for odd-parity (1-40);

- Length: The number of digits being checked for

odd-parity (1-40).

Even Parity

These settings pertain to even-parity checking, which
helps to identify card 'misreads'.

- Position: The position of the even-parity

'checksum' (1-40);

- Start: The starting position of the data being

checked for even-parity (1-40);

- Length: The number of digits being checked for

even-parity (1-40).

Special

(Miscellaneous Items)

- Door Fallback Mode: Cards to be granted

access if the door controller module is unable
to communicate with the main panel
database:

None:

No cards/tokens accepted;

Valid Token Format:

All readable

cards/tokens accepted;

Valid Site Code:

All cards/tokens with the

correct site code will be granted access;

10 Fall-back Users:

Only the users who are

assigned as 'FallBack Users'. For details,
refer to "Fall-Back Users...".

- Unlock All Doors On Fire Alarm: If selected,

all doors in all areas associated with this
panel will automatically unlock when a fire
alarm is detected by this panel.

- AutoUpdate Card Version: For fixed-ID

cards with a version number, this sets how re-
issued cards are to be handled.

= Grant access to a card with higher version

number, and update the version number for the
specific user automatically;

= Only cards that match the version number for

each user will be granted access (must update
manually when a card is re-issued).
To set the initial/actual version number for specific
card(s), refer to the section on "Users".

For additional related settings, refer to "Card Version"
(previous). Panel Version: This feature requires

V3.2

panel firmware.

Advertising