Pick-lists, Top of the form, Standard – Interlogix VEREX Director User Manual

Page 258: Extended

Advertising
background image

250

Verex Director V4.9.1 User's Guide

21-0381E v4.9.1

Pick-Lists

(bottom of the form)

-Panel Group & Panel references (optional):

This is where you select a specific panel-
group and panel in a multi-panel system
where the 'tree' is not set to show items on
a panel-by-panel basis. For more
information on this feature, refer to "Other
Desktop Choices".

- Door: This is where you select a door

to view or edit. This area shows a
reference number assigned by the
system, and the name of the selected
door, once defined;

If the Name is Shown as "Elevator" (and the
form is blank): These screens are
placeholders for elevators (click [Filter] on
the toolbar to hide elevator references).
"Offset" values for each panel determine whether
multi-panel sites will have consecutive versus
repeating door numbers. For details, refer to the
"Display Offsets" value under "System Panels and
Displayed Item-Numbers".

Top of The Form

- Name: A suitable name/location for the door;

Standard

- Module: The number (from the MODULE

screen) for the door controller module
associated with the specific reader/door.

- Port Number: Whether this is the 1

st

or 2

nd

door on the selected door-controller module;

- Type of Readers: This identifies whether there

are one or two readers associated with this door
("In Only" vs. "In and Out");

Exception: For any door between two monitored
areas, select "IN and Out" here, and set the area for
the 2

nd

reader (even if it is not present).

(Provides an 'entry delay' in both directions when the
area(s) are armed.)

- Token Format: The card/token format

associated with this door. Up to two
card/token formats are supported for each
panel, as defined through the System Access
screen.

"Wiegand" pertains to cards/tokens for readers with
Wiegand data-format (Wiegand, Proximity, etc.).
Similarly, "Magstripe" pertains to cards for readers

with magstripe output (magstripe, bar-code, etc.).
For details on setting up the card/token format, refer to
"System Card-Access Settings".

- LCD Name: A shorter version of the name to be

displayed at LCD keypads. This is assigned
automatically, and can also be changed if
desired (max. 12 chars., plain text).

- Controls Access to Area, and; Out Reader

Controls Access to Area: This shows the
area(s) associated with this door--as selected on
the tab for each reader (to follow/below);

Extended

Unlock Time

- Standard: This is the duration that the door will

unlock when access is granted for a typical
entrant/user.

- Challenged/Extended: This is the duration that

the door will unlock when access is granted for a
user who is set for "Extended
Delay/Challenged".

Auto Unlock

- Schedule / "In Schedule" / "Out of

Schedule": The schedule and conditions
required for the door to unlock automatically
based on a schedule.

If a schedule is selected, the times 'Outside' of the
schedule are treated in a similar manner to 'Inside' of
the schedule. (For example: You can have the door
unlocked inside of the active schedule, and also
unlocked after-hours, but only if/when the area is also
disarmed.)

Configuration Doors (First Tab Shown)

Advertising