Screen reference, Pick-lists, Top of the form – Interlogix VEREX Director User Manual

Page 254: Standard, Extended

Advertising
background image

246

Verex Director V4.9.1 User's Guide

21-0381E v4.9.1

Then, issue a "Send to Panel"
communications session to transfer
all settings to the associated panel.

For details, refer to "Panel Communications
and Updates".

Screen Reference

Pick-Lists

(bottom of the Form)

-Panel Group & Panel references (optional):

This is where you select a specific panel-
group and panel in a multi-panel system
where the 'tree' is not set to show items on
a panel-by-panel basis. For more
information on this feature, refer to "Other
Desktop Choices".

- Suite: This is where you select a suite-

security keypad to view or edit. This
area shows a reference number assigned by the
system, and the name of the 'suite' or keypad,
once defined;

"Offset" values for each panel determine whether
multi-panel sites will have consecutive versus
repeating keypad ID-numbers. For details, refer to the
"Display Offsets" value under "System Panels and
Displayed Item-Numbers".

Top of the Form

- Name: A suitable name/location to be

associated with the suite or keypad (such as the
suite number and/or occupant);

Standard

- Serial Number: The actual serial number of the

suite-security keypad. Tip: The serial number
is typically hand-written (5 digits) on a small
sticker on the circuit board.

- Keypad Type: Two-zone (compact) versus 8-

zone (full-featured);

Director

V4.4: Newer suite keypad models support 4

monitored sensors (inputs), one programmable output,
and 3 'panic keys'. Uses custom input circuit types.
Future: A reader may be built-in, or supported
externally.

- First User Access: Users with access to suite

keypads are reserved in blocks of 8 (such as 1

st

suite: users 1-8, 2

nd

suite: users 9-16, etc.).

This value is the lowest user-ID to pertain to this
suite/keypad. This number must be a multiple of
8, plus 1.

To set up the person associated with each user-ID,
refer to "Users (Entrants / Panel Users)".
Tip: If desired, you can automatically reset the users
for all defined keypads (or up to a desired one) to the
default of consecutive blocks of 8: Select the highest
numbered keypad to be affected. Then, right-click
anywhere on its form, and select Auto Fill User
Offset
. When asked to confirm, select Yes.

-------------------------

- Last Communicated: During each

communications session, the software will check
the keypad type, and display it here.

- User Access Range: This shows the range of

user ID numbers to pertain to this suite/keypad,
based on the 'First User Access' value (prev.).

-------------------------

- Floor: The is the floor associated with the

suite/facility

(or the lower of two for suites that can be

accessed from two floors)

.

- Additional Floor: Select this if the suite/facility

can be accessed from two floors.

- LCD Name: A shorter version of the name to be

displayed at LCD keypads. This is assigned
automatically, and can also be changed if
desired (max. 12 chars., plain text).

- Digital Account ID: Future Use. For central

monitoring.

- Report Mode: Future Use. For central

monitoring.

Extended

- Entry Delay: The duration that the monitoring of

'Entry' points will be held/delayed to allow an

Configuration Suite Security