282

Verex Director V4.9.1 User's Guide

21-0381E v4.9.1

Area

(if event occurs in a specific area):

Area

Function key #0, #1, ...#9

(Pertains to keypad functions keys)

Area On

When the area is fully armed (ON).

Area

Stay 2 (future use)

When the arming level is STAY 2 (future)

Area Stay

1

When the arming level is STAY.

Area

Stay (1 or 2)

When armed to STAY. (Stay 2 = future)

Area Off

When the arming level is OFF

Area Not

On

When the arming level is "Off" or "Stay".

Area Not

Off

When the arming level is "Stay" or "ON".

Area

Alarm

When area is in ALARM. Resets when
point(s) restore or follows siren timeout
(includes pseudos & tampers)

Area Was

In

Alarm

When area WAS IN ALARM. This is only for
input points in alarm e.g. NOT for system
trouble (clears when alarmed areas are
turned off then back on again)

Area

Siren Fire (1 sec.)

Follows ALARM siren - steady for BURG /
EMERG and provides 1 sec ON/OFF for
FIRE

Area

Siren Fire (2 sec.)

Follows ALARM siren - steady for BURG /
EMERG and provides 2 sec ON/OFF for
FIRE

Area

Sonalert (E/E tones on Stay)

Follows sonalert, chime & provides Entry/Exit
tones when armed to STAY & ON

Area

Sonalert (No E/E tones on Stay)

Follows sonalert, chime & does not provide
Entry/Exit tones when armed to STAY but
provides Entry/Exit tones in ON

Area

Extended Delay Entry Tones

Follows Garage/extended delay Entry Tones

Area Bypasses

When any point in this area is BYPASSED

Area Fire

When any ‘FIRE’ type point in this area is in
alarm

Area Hold-Up

When any ‘HOLD UP’ type point in this area
is in alarm

Area

Auxiliary Alert

When any ‘AUXILIARY ALERT’ type point in
this area is in alarm.

Area Vault

When any ‘VAULT / SAFE’ type point is in
alarm.

Area Burglary

When any ‘BURGLARY’ type point in this
area is in alarm.

Area Supervisory

When any ‘Supervisory' point is in alarm.

Area Pseudo

When any 'Pseudo' condition is in effect.

Area Walk

Test

Area is in ‘Walk’ or ‘Hold-up’ test.

Area Entry

/

Exit

When area Entry / Exit delay is in progress –
provides a steady output (STAY & ON).

Area Entry

When area Entry delay is in progress -
provides a steady output (STAY & ON).

Area Exit

When area Exit delay is in progress -
provides a steady output (STAY & ON).

Area Ready

When the area is ‘Ready To Arm’ - i.e. all
points are secure.

Area Open

Window

When the active/open window of the area's
schedule is in effect.

Area Closing

When the area schedule is expiring in 15
minutes.

Area Door

Unlocked

Area Door

Locked

Out

Area Door

Held

Open

Area Door

Forced

Area Door

Tamper

Door Tampers (door contact condition: no
EOL resistor etc.)

Area Door

Open

Area Door

Secure

Area

Door Sensor Trouble

Door Sensor Troubles (magnetic bond
sensor not ok)

Area

Panic Token Detected

Advertising