Screen reference, Pick lists, On this form – Interlogix VEREX Director User Manual

Page 279

Advertising
background image

21-0381E v4.9.1

Welcome Report Control Admin

Sys Config

Tech-Ref

271

Screen Reference


Pick Lists

(bottom of the form)

-Panel Group & Panel references (optional;

bottom of the form): This is where you
select a specific panel-group and panel in a
multi-panel system where the 'tree' is not
set to show items on a panel-by-panel
basis. For more information on this feature,
refer to "Other Desktop Choices".

- Custom Point Type (bottom of form):

This is where you select a custom
point-type to view or edit. This area shows a
reference number assigned by the system, and
the description, once defined;

Note: Similar to

physical items in a system, each custom point-type
pertains to an individual panel.

On This Form

(Standard  )

- Name: A suitable name indicating the operation

or usage for this custom point type;

- Preprocess:

Either the duration that the

point must REMAIN triggered before an
alarm will be audited, or the point type /
operation;

Door: The 'Door' selection is normally used with doors
that are monitored, but not electronically controlled for
personnel access. For access-controlled doors, a
dedicated 'Door Contact' input is provided on the door-
control module (which is set up through the Door
screen). As well, door inputs cannot be set for a 24-hr
monitoring, and cannot be bypassed (regardless of
whether "bypassable" is selected or not).
Extended: This pertains to garage door sensors, and
other applications where a longer delay time is
desired. With this setting, the area "Extended" delay
will apply, and the area can be armed while the input
is 'tripped'.
Keyswitch Arming/Disarming: With 'pre-process' set
to "Keyswitch...", the "Level" setting provides
selections for "Arm" and "Disarm". The chime
operation changes as well: If "Chime (

)", and the

area is set for "Stay on Fail to Exit", the area will be
armed to 'Stay' if no users exit after turning the switch
(not-Ok to Ok). Conversely, if the chime is not
selected, the "Stay on Fail to exit" setting will be
ignored (the area will fully arm to 'On'). Note: With an
arming keyswitch, disarming is typically done through
an LCD keypad.

Guard Tour: This pertains to guard-tour checkpoints
(stations). For this application:
+ The 'class' should be set as "supervisory";
+ The 'level' will typically be set as "24hr";
+ Any "Transmit" selections will be ignored (guard-tour

point activity is referenced locally during the
monitoring of a guard-tour).

WorkLate: This pertains to a button that can be
pressed (during the pre-arm cycle) to delay the
scheduled closing time for the area associated with
the input-point. To set the time extension for
WorkLate buttons in a specific area, refer to the "Work
Late Input Point" setting under "Areas and Related
Settings".
Notice: Outside of the 15 minute pre-arm cycle, a
worklate point acts as a standard burglary point. This
allows (for example) a motion sensor to function as a
worklate trigger during the pre-arm cycle, and as a
standard motion sensor during its monitored times.
Be careful to set the “Level” and “Transmit / Sonalert /
Siren” values as suitable for your specific application.
Command Point: This allows a button or sensor to
command a device associated with:

 Any specific

panel,

 Any area or door number (ID) across all

panels, or

 All panels/areas/doors of an account.

Tip: The actual command is selected when setting up
the specific sensor(s)/input-point(s).
Related Topic:

Configuration, Input Points,

Command

.

See: Input Points—Monitored Sensors (previous).
Activity Monitor: This 'officially' detects activity in an
area. For details, refer to "

Activity Monitoring and

Auto-Arming

" in the 'Area' configuration topic.

Battery Fail, Mains Fail: these inputs are design to
support power supply units, which are not fully
integrated - not monitored by the xL system, but have
a "battery/mains fail" outputs. The ouptuts can be
connected to the inputs in order to monitor the state of
the power supply. Preprocess Delay of these points is

Configuration Custom Point Types