Input Points—Pre-Defined Sensor Types

Burglary Points:

Type Arming

Level

Preprocess

Class

By-

pass

Chime

Tx

Off

Tx

Stay

Tx

On

Sonlrt

Off

Sonlrt

Stay

Sonlrt

On

Siren

Off

Siren

Stay

Siren

On

Entry

Door Perimtr Door

(area

1)

Burg

--

--

--

--

Entry Route

12hr

E/E Route

Burg

--

--

--

-- --

Perimeter Perimeter

Immed Burg

--

--

--

Interior Motion

12hr

Immed

Burg

--

--

--

--

-- --

FAP - Motion

12hr

FAP

Burg

--

--

--

--

-- --

Day Warning

24hr

Immed

Burg

--

--

-- --

24hr Burglary 24hr

Immed

Burg

--

Life/Safety Points:

Type Arming

Level

Preprocess

Class

By-

pass

Chime Tx Off

Tx

Stay

Tx On Sonlrt

Off

Sonlrt

Stay

Sonlrt

On

Siren

Off

Siren

Stay

Siren

On

Fire - A 24hr Immediate

Fire-A

Fire 24hr

15s

delay Fire

Fire 24hr

Immediate

Fire

Hold-up 24hr Immediate

holdup

Aux Alert

24hr

Immediate

Emerg

Supervisory Points:

Type Arming

Level

Preprocess

Class

By-

pass

Chime Tx Off

Tx

Stay

Tx On Sonlrt

Off

Sonlrt

Stay

Sonlrt

On

Siren

Off

Siren

Stay

Siren

On

Supervisory 24hr

Immediate Spvsr

Battery Fail

24hr

Battery Fail

Spvsr

Mains Fail

24hr

Mains Fail

Spvsr

Local Points:

Type Arming

Level

Preprocess

Class

By-

pass

Chime

Tx

Off

Tx

Stay

Tx

On

Sonlrt

Off

Sonlrt

Stay

Sonlrt

On

Siren

Off

Siren

Stay

Siren

On

Local - 24hr

24hr

Immed

Burg

Local-Stay&On Perimeter Immed

Burg 

Local-
Stay2 & ON

Perimeters Immed

Burg 

Local -
ON only

12 hr

Immed

Burg


Legend:

 The 'Class' setting determines the type of alarm message to be transmitted;
 Bypass means whether or not the input point will be bypassable;
 Chime pertains to whether or not the triggering of the input will cause audible tones at keypads in the

area (normally used with Entry points/routes to let you know that someone has entered);

 Tx Off, Stay, and On pertain to the arming levels for which activation of the input point will cause an

alarm to be transmitted to the monitoring station;

 Sonlrt Off, Stay, and On pertain to the arming levels for which activation of the input point will cause

keypad 'sonalerts' in the area to be sounded for one second.

 Siren Off, Stay, and On pertain to the arming levels for which activation of the input point will cause

siren outputs in the area to be sounded.