21-0381E v4.9.1

Welcome Report Control Admin

Sys Config

Tech-Ref

251

To have the door simply re-lock at the closing time, set
the "In Schedule" value as desired, and set the "Out of
Schedule" value to "Locked".
To have the door unlocking follow the area arming-
state only, set the schedule to "None", and "In
Schedule" to either "Area is Off", or "Area is
Stay/Off
", as desired.
If you do not want the door to unlock automatically
based on a schedule and/or the area arming-state, set
the "Schedule" to "None", and the 'In Schedule' value
to "Locked".

Circuit

With converted TDC/PDC door controllers, this setting
does not apply.

- Reader Tamper Circuit: This is the type of

circuit/wiring used with the reader tamper circuit
for this door.

Not Required: This disables the reader tamper input
(i.e., the tamper input will not be monitored).
Converted TDC/PDC Door Controllers: These units
do not support dedicated/separate reader tamper
monitoring.

- Door Circuit: This is the type of circuit/wiring

used with the door contact for this door.

-------------------------

- Process Reader Tamper as Input Point:

Future use.

Other

- Door Arming Level: The area arming levels

for which the door is to be monitored.

Tip: You may wish to use "Stay and On" with doors
used to enter the facility, and "On Only" for all doors
within the facility.

- Bi-Colour LED Mode: Select this if the reader

at this door has a single bi-color LED (instead of
the two separate LEDs). This setting

must

also

be used if an 'arming station' is present.

Note: Arming-station wiring differs from other readers
(ensure the proper installation instructions have been
followed).

- Entry Detect: If selected (), persons will not

be considered "In" the new area if they are
granted entry, but do not open the door.

Tip: This affects the in/out status of applicable users,
and allows them to badge again to gain entry with
antipassback turned on (see "Detect Antipassback", to
follow / below).
Related: Configuration Areas

Counting and Auto Arm.

Note: This does NOT affect 'Activity' detection
(Cfg.Areas Activity).

- Disable *30 – Arm All Areas: (Director ≥

v4.80) Select this to disable arming all areas in
readers assigned to chosen doors.

Note: The XL Panel ≥ 4.58g is required.