This allows a button or sensor to command an aspect
or device for any (or all) panels in an account. This tab
appears only if the 'Point Type' (previous/above) is a
'custom type' set as a 'command point'.
Related Settings:

Configuration, 

Custom Point

Types

.

See: Input Points—Custom Point Type (to follow).
Tip: For additional operating details, refer to "Notes /
Attention" at the end of this section.

- Command Type: Whether the command is to

affect area(s), door(s), or system (panel-wide)
aspects.

Tip: Select a command type, and then look under
"Command" to see the available choices.

- Command: The specific action to occur when

the sensor/input is tripped.

Items separated with a slash (/): This performs a
'toggle' operation between the indicated states each
time the sensor/input is tripped.
(Force and Exit Delays): Exit delays means the
affected areas will get an exit delay warning rather
than arming immediately. Force (short for 'force arm')
means if a point is insecure, the area still arms, and
then the point will be reported as 'In Alarm').
Remote RTE: Momentary unlock using the standard
duration.
Challenged RTE: Momentary unlock using the
extended/challenged duration.

Pertaining to Bad Card/PIN: Refer to

Bad

Card/PIN

under "Account-Wide Panel Settings".

Pertaining to User Count and Area Activity: Refer

to

Counting

and

Activity

in the 'Area'

configuration topic.
Various/Other: See the command lists at the end of
"Maps and Video (Visual Monitoring &
Status/Control)".

- Multiple Panel Command: Whether or not the

command is to affect all panels in the specific
account (versus selecting a specific panel).

Note: For area and door commands, this would
typically be used with the "All" selection. (If you select
a specific door or area number, the command will
affect that area/door number for all panels).

- Area / Door: For area and door commands,

select the target item here.

Without Multiple Panel Command: This lists areas or
doors for each panel (in the panel-order as shown in
the 'tree').
With Multiple Panel Command: This lists area/door
numbers (or "All"), and will affect all panels in the
account.

- Panel: For a single-panel command, select the

panel here.

-------------------------

Blue Text at the Bottom

This shows a reminder of the your selected
command, and the selected panel (if
applicable).

Tip: If a panel is NOT shown, this means the
command will affect all panels (i.e., a 'multi-panel
command').

-------------------------

Notes / Attention:

 Multi-panel and cross-panel commands are routed

through the Director software. As such, the source
and target panels must be communicating with the
Director software when the input/button is tripped.

 Other than issuing the specific action, command-

points are monitored only for 'Tamper' conditions (re:
Transmit, Sonalert, and Siren).

 Command Points are fixed as 'Supervisory'.
Related Settings:

Configuration, 

Custom Point

Types

.

See: Input Points—Custom Point Type (to follow).








About Video Events