Checking status & controlling items, Introduction to status & control – Interlogix VEREX Director User Manual

Page 81

Advertising
background image

21-0381E v4.9.1

Welcome Report

Control

Admin Sys

Config Tech-Ref

73

Introduction to Status & Control

The Status and Control Feature

VEREX Director can monitor the status of most
system, area, and device aspects, and allows
controlling the system on an area-by-area
basis, or for individual doors or input points.

Also See (

 V4.0):

+ Visual Status and Control (Maps and Cameras)
+ To Connect: "New Installation? Try the Wizard

The status for individual items at specific site
can be checked manually, as desired. As well,
the status toolbar allows monitoring a desired
account for various items (sirens, fire alarms,
other alarms, and trouble conditions), and
provides a quick way to view the details for
each item.

Items to be available under Control & Status depend on
the authorities associated with the user ID and PIN
entered when logging into "Control & Status". If you
were not asked to enter a user ID and PIN, then one
has been set up for automatic entry in your operator
settings. For details, refer to the section on
"Operators".
Status monitoring (either manually, or through the
status toolbar), requires that the VEREX Director
system be connected with the specific panel(s), and the
specific devices must be communicating.
If an item is listed as 'Off-Line', this typically indicates
either a communications problem, or a set-up error
(such as an incorrect module/POD serial number).
If all items on a screen are grey in color, this generally
means that you are either not connected with the
specific panel, or the applicable module is 'off-line' (not
communicating).
Items changed through 'Control & Status' (such as
unlocking a door, or locking-out cards, etc.) remain in
effect until changed by another person or by a
scheduled Configuration setting.

Connecting to the Associated Panel(s),
An Overview:
1)
See if you're already connected by

checking the status bar at the bottom
of the monitoring window.

Multi-Account systems: Ensure your desired
account is selected (click [Account Folders]
in the tree, and then double-click the specific

account).

2) If not connected, check to ensure the

communication software is running
on the specific PCs.

Detail: If the LCD/Telephone icon on the
Windows taskbar is black-and-white (color =
running), start the communications service by
right-clicking the icon, and selecting "Start
Communications".
Related Topic: Serial Port / Modem Setup
(Communications Manager)

3) Select

Communications

from your

MyTools bar, or click

[Communications]

in the 'tree', and

select

Pending/OnLine

.

4) Click the

[+]

at the bottom of the

form, or right-click the form, and
select

Add New

from the pop-up

menu. Then, select the desired
panel(s) (double-click to select), and
set "Action" to "Normal", and
"Frequency" to "Stay Connected" ().
(Click

OK

when finished.)

5) Check that the connection is made, and

watch for the panel updates to occur.

(Click the 'Panel Group', and look for the status on
the right side of the screen.)

Note: Control & Status features will be available after
the panel updates have finished (look for a connection
state of 'Connected' and 'Idle State'.)
Also See (Related Topics):
+ "Panel Communications and Updates"

Accessing the Control and Status
Topics for a Panel

See if you're already connected with the
panel(s) by checking the status bar at the
bottom of the monitoring window.

Multi-Account Systems: First select [Account
Folders]
in the 'tree', and double-click the desired
account.

If not presently connected, initiate a connection
as described previously/above.
Then, access your desired topic:

Using the MyTools Bar: Select the desired Control
and Status topic from the MyTools bar (and login with
your user ID and PIN if prompted for this).
Using the Tree: Click your site/account button in the

Checking Status & Controlling Items