Pick-list (bottom of the form), Standard, Alternate – Interlogix VEREX Director User Manual

Page 235

Advertising
background image

21-0381E v4.9.1

Welcome Report Control Admin

Sys Config

Tech-Ref

227

Pick-List (bottom of the
form)

-Panel (optional): If the tree is not set to

show items on a panel-by-panel basis,
you will be able to select a panel here
(for systems that have more than one).

A "Panel Group" reference may also be
shown here, or you can set the 'tree' to list
configuration topics separately for each
panel. For more information, refer to "Other
Desktop Choices".

Standard

and

Alternate

(for 1

st

& 2

nd

card formats to be used at the

same time)

Two card types can be set up, allowing either
Wiegand / Prox and Magstripe/barcode, or two types of
Wiegand / Prox cards to be used with each specific
panel.
All length values refer to number of characters for
magnetic stripe cards (MS), or number of bits for
Wiegand technology (W).

- Token Format: This allows defining

parameters for the basic card/token types (as
selected for each specific reader).

"Wiegand" pertains to cards/tokens for readers with
Wiegand data-format (Wiegand, Proximity, etc.).
Similarly, "Magstripe" pertains to cards for readers
with magstripe output (magstripe, bar-code, etc.).

-------------------------

- [Wiegand 26]: This automatically sets the card-

format values for the standard 26-bit Type-A
Wiegand format.

- [Wiegand 36]: This automatically sets the card-

format values for the proprietary 36-bit Wiegand
format.

Card Site (Site/System Code)

- Site Required: This enables/disables site code

checking. If selected, cards without one of the
specified site codes will be denied access.

- Site Code 1, 2, 3: If site-code checking is

enabled, only cards encoded with one of these
site codes will be allowed access at this site
(e.g., 0004, 1234, 9999).

- Position: The start position of the site code

(1-40);

- Length: The length of the site code (MS: 1-4;

W: 1-16).

Card Version (Version-Number)

This feature requires

V3.2 panel firmware and

V1.5

door/elevator controller module firmware. For an
additional setting, refer to "AutoUpdate Card Version",
under  Special  (to follow).

- Version Required: This enables/disables

version number checking (allows fixed-ID cards
to be re-issued if lost or stolen).

- Position: The starting position of the version

number (1-40).

- Length: The length of the version number (MS:

1-2; W: 1-8).

Card ID

- Position: The starting position of card ID

number (1-40);

- Length: The length of card ID number (MS: 4-9;

W: 1-32).

32-Bit Cards: Supported with panel firmware

V3.2,

and door/elevator controller module firmware

V1.5

(prev. 20 bit / 6 digits).
V3.2 panels: MaxID=999999999;

V3.31 Panels:

MaxID=4

294

967

295.

- Bits per Card: The length of the card data in

bits (Wiegand), or characters (magnetic stripe).
This can be up to 40.

- Bits per Character

(magstripe only)

: The number

of bits used to identify each character of data on
a magstripe card (future use; fixed as

4

).

Odd Parity

These settings pertain to odd-parity checking, which
helps to identify card 'misreads'.

- Position: The position of the odd-parity

Configuration System Access

Note: For a system set for intrusion-only (under Account Information),
the "Access" tab will appear as "Token Format".

Advertising