112

8.2 Multicast application

PSSnet SHL - Basic Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

„

Parameter values

The parameters
– Max. Response Time,
– Send Interval and
– Group Membership Interval
have a relationship to each other:

Max. Response Time < Send Interval < Group Membership In-
terval.

If you enter values that contradict this relationship, the device then re-
places these values with a default value or with the last valid values.

Parameter

Protocol
Version

Value range

Default setting

Max. Response Time

1, 2
3

1-25 seconds
1-3598 seconds

10 seconds

Send Interval

1, 2, 3

2-3599 seconds

125 seconds

Group Membership Interval

1, 2, 3

3-3600 seconds

260 seconds

Table 7: Value range for

- Max. Response Time
- Send Interval
- Group Membership Interval