1 configuring the device status – Pilz PSSnet SHL 8T MRP User Manual

Page 157

Advertising
background image

Operation diagnosis

158

9.2 Monitoring the device status

PSSnet SHL - Basic Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

Note: With non-redundant voltage supply, the device reports the absence of
a supply voltage. You can prevent this message by feeding the supply volt-
age over both inputs, or by switching off the monitoring

(see on page

162

„Monitoring the device functions via the signal contact“)

.

9.2.1 Configuring the device status

Note: The above CLI commands activate the monitoring and the trapping
respectively for all the supported components. If you want to activate or
deactivate monitoring only for individual components, you will find the
corresponding syntax in the CLI manual or in the help (Input ?) of the CLI
console.

…

Select the Diagnostics:Device Status dialog.

…

In the "Monitoring" field, you select the events you want to monitor.

…

To monitor the temperature, you set the temperature thresholds in
the Basics:System dialog at the end of the system data.

enable

Switch to the Privileged EXEC mode.

configure

Switch to the Configuration mode.

device-status monitor all er-
ror

Include all the possible events in the device
status determination.

device-status trap enable

Enable a trap to be sent if the device status
changes.