Loading the software via file selection, 3 loading the software via file selection – Pilz PSSnet SHL 8T MRP User Manual

Page 69

Advertising
background image

Loading software updates

70

4.3 Loading the software via file selec-

tion

PSSnet SHL - Basic Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

4.3 Loading the software via file

selection

For an update via a file selection window, the device software must be on a
data carrier that you can access via your PC.

…

Select the Basics:Software dialog.

…

In the file selection frame, click on “...”.

…

In the file selection window, select the device software (device.bin)
and click on “Open”.

…

Click on “Update” to transfer the software to the device.

The end of the update is indicated by one of the following messages:

X

Update completed successfully.

X

Update failed. Reason: incorrect file.

X

Update failed. Reason: error when saving.

X

File not found (reason: file name not found or does not exist).

X

Connection error (reason: path without file name).

…

After successfully loading it, you activate the new software:
Select the Basic Settings:Restart dialog and perform a cold

start.
In a cold start, the device reloads the software from the non-volatile
memory, restarts, and performs a self-test.

…

In your browser, click on “Reload” so that you can access the device
again after it is booted.