Pilz PSSnet SHL 8T MRP User Manual

Page 161

Advertising
background image

Operation diagnosis

162

9.3 Out-of-band signaling

PSSnet SHL - Basic Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

9.3.3 Monitoring the device functions via the

signal contact

„

Configuring the operation monitoring

„

Displaying the signal contact

The device gives you three additional options for displaying the status of
the signal contact:

X

LED display on device,

X

display in the Web-based interface,

X

query in the Command Line Interface.

…

Select the Diagnostics:Signal Contact dialog.

…

Select "Monitoring correct operation" in the "Mode signal contact"
frame to use the contact for operation monitoring.

…

In the "Monitoring correct operation" frame, you select the events
you want to monitor.

…

To monitor the temperature, you set the temperature thresholds in
the Basics:System dialog at the end of the system data.

enable

Switch to the Privileged EXEC mode.

configure

Switch to the Configuration mode.

signal-contact 1 monitor all Includes all the possible events in the operation

monitoring.

signal-contact 1 trap enable Enables a trap to be sent if the status of the oper-

ation monitoring changes.