Setting up configuration environment

188

A.2 Setting up DHCP Server Option

82

PSSnet SHL - Basic Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

Figure 67: Default setting for the fixed address assignment

…

In the Hardware address field, you enter the Circuit Identifier

and the Remote Identifier (see "DHCP Relay Agent" in the "Web-

based Interface" reference manual).
With Hardware address you identify the device and the port to which

that device is connected, to which you want the assign the IP address

in the line below it.

The hardware address is in the following form:

ciclhhvvvvssmmpprirlxxxxxxxxxxxx

X

ci: sub-identifier for the type of the circuit ID

X

cl: length of the circuit ID

X

hh: Pilz ID: 01 if a Pilz device is connected to the port, otherwise 00.

X

vvvv: VLAN ID of the DHCP request (default: 0001 = VLAN 1)

X

ss: socket of device at which the module with that port is located to
which the device is connected. Enter the value 00.

X

mm: module with the port to which the device is connected.

X

pp: port to which the device is connected.

X

ri: sub-identifier for the type of the remote ID

X

rl: length of the remote ID

X

xxxxxxxxxxxx: remote ID of the device (e.g. MAC address) to which a
device is connected.