System monitor, 1 system monitor – Pilz PSSnet SHL 8T MRP User Manual

Page 15

Advertising
background image

Access to the user interfaces

16

1.1 System Monitor

PSSnet SHL - Basic Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

1.1 System Monitor

The system monitor enables you to

X

select the software to be loaded

X

perform a software update

X

start the selected software

X

shut down the system monitor

X

delete the configuration saved and

X

display the boot code information.

„

Opening the system monitor

…

Use the terminal cable (see accessories) to connect
– the V.24 socket (RJ11) to
– a terminal or a COM port of a PC with terminal emulation based on

VT100

(for the physical connection, see the "Installation" user manual).

…

Start the terminal program on the PC and set up a connection with the
device.

When you boot the device, the message
"Press <1> to enter System Monitor 1"
appears on the terminal.

Speed

9,600 Baud

Data

8 bit

Parity

none

Stopbit

1 bit

Handshake

off

Table 1: Data transfer parameters