1 controlling the signal contact – Pilz PSSnet SHL 8T MRP User Manual

Page 160

Advertising
background image

Operation diagnosis

PSSnet SHL - Basic Configuration

Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern

9.3 Out-of-band signaling

161

9.3.1 Controlling the signal contact

With this mode you can remotely control every signal contact individually.

Application options:

X

Simulation of an error during SPS error monitoring.

X

Remote control of a device via SNMP, such as switching on a camera.

9.3.2 Monitoring the device status via the signal

contact

The "Device Status" option enables you, like in the operation monitoring, to
monitor the device state

(see on page

157

„Monitoring

the

device

status“)

via

the signal contact.

…

Select the Diagnostics:Signal Contact 1/2) dialog.

…

In the "Mode Signal contact" frame, you select the "Manual setting"
mode to switch the contact manually.

…

Select "Opened" in the "Manual setting" frame to open the contact.

…

Select "Closed" in the "Manual setting" frame to close the contact.

enable

Switch to the Privileged EXEC mode.

configure

Switch to the Configuration mode.

signal-contact 1 mode manual Select the manual setting mode for signal contact

1.

signal-contact 1 state open

Open signal contact 1.

signal-contact 1 state closed Close signal contact 1.

Advertising