Input/output avalon-mm slave module – Altera RapidIO MegaCore Function User Manual

Page 98

Advertising
background image

4–52

Chapter 4: Functional Description

Logical Layer Modules

RapidIO MegaCore Function

August 2014

Altera Corporation

User Guide

Input/Output Avalon-MM Slave Module Timing Diagrams

Figure 4–27

shows the timing dependencies on the Avalon-MM slave interface for an

outgoing RapidIO NREAD request.

Figure 4–28

shows the timing dependencies on the

Avalon-MM slave interface for an outgoing NWRITE transaction. Both transaction
requests originate on the Avalon-MM interface of the slave module. The timing
diagrams in

“Input/Output Avalon-MM Master Module Timing Diagrams” on

page 4–40

show the same transactions after they are transmitted on the RapidIO link

and received by an Altera RapidIO IP core link partner, when they are sent out as
Avalon-MM requests by an Input/Output Avalon-MM master module in the partner
RapidIO IP core.

Figure 4–27. NREAD Transaction on the Input/Output Avalon-MM Slave Interface

sysclk

io_s_rd_chipselect

io_s_rd_waitrequest

io_s_rd_read

io_s_rd_address[31:0]

io_s_rd_readdatavalid

io_s_rd_readdata[31:0]

io_s_rd_burstcount[7:0]

io_s_rd_readerror

Adr0

Adr1

00000000

r0

r1

r2

01

02

Figure 4–28. NWRITE Transaction on the Input/Output Avalon-MM Slave Interface

sysclk

io_s_wr_chipselect

io_s_wr_waitrequest

io_s_wr_write

io_s_wr_address[31:0]

io_s_wr_writedata[31:0]

io_s_wr_byteenable[3:0]

io_s_wr_burstcount[7:0]

00000000

AdrA

AdrB

w0

w1

w2

w3

w4

w5

F

02

04