T1/E1 & T3/E3 Commands

2-56 Configuring T1/E1 and T3/E3 Subsystems

cablelength

For T3 controllers only

This command specifies the distance of cabling from the XSR to the network equipment for a T3 
NIM card only.

Syntax

cablelength feet

Syntax of the “no” Form

The no form of this command sets the cablelength to the default value:

no cablelength

Mode

Controller configuration: 

XSR(config-controller xx)#

Default

224 feet

Example

The following example configures the T3 controller in slot 1, card 2 with line source clocking, M13 
framing, in channelized mode, and a cablelength of 225 feet:

XSR(config)#controller t3 1/2/0
XSR(config-controller<T3-1/2/0>)#channelized
XSR(config-controller<T3-1/2/0>)#clock source line
XSR(config-controller<T3-1/2/0>)#framing m13
XSR(config-controller<T3-1/2/0>)#cablelength 225

cablelength long

For T1 controllers only

This command decreases the pulse from the transmitter for long haul applications on T1 
controllers only. In long haul applications (length of the haul longer than 655ft, CSU interface) the 
transmit pulse masks are optionally generated according to ANSI T1.403 to reduce crosstalk on 

Note: Although you can specify cable length from 0 to 450 feet, the XSR recognizes only two
ranges: 0 to 224 and 225 to 450. For example, entering 35 feet selects the 0 to 224 range. If you
later change the cable length to 40 feet, there is no change because 40 falls within the 0 to 224
range. But, if you change the cable length to 350, the 225 to 450 range is selected. The actual length
you enter is stored in the configuration file.

feet

Distance to set the cable length, ranging from 0 to 450 feet.