T1/E1 and T3/E3 Clear and Show Commands

XSR CLI Reference Guide 2-79

FEAC code received 

Displays the last 4 FEAC codes or commands that were received. Applicable 
for C‐bit parity framing only, per ANSI T1.105‐1995. This field are intended for 
T3 line debugging by carrier personal.

Values (the last four codes are just displayed, subsequent codes will overwrite 
current ones) listed are as follows:

DS3 Eqpt. Failure (SA)

DS3 LOS

DS3 Out‐of‐Frame

DS3 AIS Received

DS3 IDLE Received

DS3 Eqpt. Failure (NSA)

Common Eqpt. Failure (NSA)

Multiple DS1 LOS

DS1 Eqpt. Failure  (SA)

Single DS1 LOS

DS1 Eqpt. Failure (NSA)

No code is being received

Command values are as follows:

Loopback Activate 

Loopback Deactivate

DS3 Line

DS1 Line 1 to 28 (displayed but not acted upon)

DS1 Line All (displayed but not acted upon)

Framing is

Framing type on the controller:

C‐BIT Parity

M13

G.751

Bypass

Line Code is

Line coding format on the controller: B3ZS

Clock Source is

Clock source on the controller: Internal or Line.

Line Code Violations (Valid for C‐
bit, M13, g751 & bypass)

A count of both Bipolar Violations (BPVs) and Excessive Zeros (EXZs) 
occurring over the accumulation period. An EXZ increments the LCV by one 
regardless of the zero string’s length.

P‐bit Coding Violation (Valid for 
C‐bit & M13)

For all DS3 applications, a PCV error event is a P‐bit parity error event. A P‐bit 
parity error event is the occurrence of a received P‐bit code on the DS3 M‐
frame that is not identical to the corresponding locally calculated code.

C‐bit Coding Violation (Valid for 
C‐bit)

For C‐bit parity applications, the CCV is the sum of coding violations reported 
via the C‐bits. For C‐bit parity, it is the sum of CP‐bit parity errors occurring 
during the accumulation interval.

P‐bit Err Secs (Valid for C‐bit & 
M13) 

PES is a second with one or more PCVs, one or more Out‐of‐Frame defects, or 
a detected incoming AIS. This gauge is not incremented when unavailable 
seconds are counted.