Parameter descriptions – Enterasys Networks X-Pedition XSR CLI User Manual

Page 83

Advertising
background image

T1/E1 and T3/E3 Clear and Show Commands

XSR CLI Reference Guide 2-77

Latest II III IV
No Code No Code No Code No Code

Alarms Detected:
LOS LOF TxAIS RxAIS TxRAI RxRAI LOOP PayLd
X X X

24 Hour Statistics cleared: MAY 04 22:33:47
Current time: MAY 04 22:34:13

Interval LVC PCV CCV PES PSES SEFS UAS LES CES CSES
Total 4352 0 0 2 2 2 2 2 2 2
Current 4352 0 0 2 2 2 2 2 2 2
( 28s)

Note:
The 24 hour statistics is applied differently based on the selected farming type,
the following table marks the valid fields by a *

LCV PCV CCV PES PSES SEFS UAS LES CES CSES

T3 C_bit * * * * * * * * * *
T3 M13 * * - * * * * * - -

E3 G751 * SES * * *
E3 Bypass * *

Parameter Descriptions

Rx signal level ‐0.0DB 
(Accuracy:+/‐3DB) [string]

String values can be:

NULL string: port locked on the signal; range 0 to 43.4

ʺnot validʺ: port could not lock on the signal 0 to 43.4

ʺhigh noise floorʺ: port locked on the signal, but signal is noisy  0 to 43.4.

This line determines if the port is connected to a valid T1/E1 signal. The port 
will not function if the signal is ʺnot validʺ and will act unpredictable if it is 
ʺhigh noise floorʺ. The line displays only if the Drop&Inset NIM is configured 
for data and voice mode. If it is used in data mode, it will not display.

1 1 1 1 1 1 1 1 1 1 2 2 2 2 2

Time slot number TENs.

1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 
0 1 2 3 4

Time slot number units.

Advertising