Reconfigure I/O ports and call registers

Procedure 19
Reconfiguring I/O ports and call registers

1

Evaluate the number of call registers and 500 telephone buffers that are
configured for the system (suggested minimum values are 4500 and 1000
respectively). If changes are required, reconfigure the values in LD 17:

2

Print the Configuration Record to confirm the changes made in Step 1:

End of Procedure

Procedure 20
Switching call processing to the CP PM Call Server

1

Plug the CP PM Call Server port labeled ELAN into the ELAN subnet.

2

Initialize (using the init button) the CP PM card.

3

Wait for “DONE” and then “INI” messages to display before you continue.

End of Procedure

LD 17

Load program

500B 1000

Use 1000 as a minimum value

NCR 20000

Use 20000 as a minimum value

****

Exit program

LD 22

Load program

REQ PRT

Set the print option

TYPE CFN

Print the configuration

****

Exit program