Installing software on the CS 1000E

NN43041-310

Standard 01.11

October 2008

The MGC must be given a superloop and shelf reference on the Call Server
(see Table 13)

.

Procedure 29
Configuring the MGC on the Call Server

Note: Initial configuration of the MGC is command line ONLY.

The MGC is shipped with “gold” software in onboard flash memory. If
centralized software upgrade is enabled on the Call Server, the MGC is
upgraded automatically (or it can be upgraded manually through LD 143).

There are two ways to enter mgcsetup:

If no IP information exists on the MGC, it will boot directly into the
setup menu.

If IP information does exist, the prompt “To invoke install menu or
bypass loadware upgrade enter CONTROL-I” appears.

Table 13
MGC superloop configuration

Loop

Shelf

IPMG #

000

0

1

000

1

2

004

0

3

004

1

4

008

0

5

...

...

...

096

0

49

096

1

50