Communication Server 1000E

Installation and Commissioning

19-inch rack

All CS 1000E system components are mounted in a customer-supplied
19-inch rack. Ground the rack and equipment to the NTDU6201 Ground Bar.

System cables

Table 9 on

page 76

lists the cables required with the CS 1000E system.

The base marketing package NTHU53AA provides an NTRC17 crossover
cable to connect the LAN2 ports of the two core CP PM Call Servers. It also
contains two MRV Terminal Server cables (NTDU6302) to connect from
COM port 1 of both core CP PM Call Servers to the MRV Terminal Server.

Note: Order the proper power cord for your region.

Power

Power cord connector is located on the left-hand
corner on the unit’s backplane.

Power supplies are factory installed and not
customer replaceable.

Unit is AC powered (120 V AV @ 1.58 amps).

Cooling

Forced air cooling with side-to-side air flow.

The fans run at a single speed.

Ensure that equipment ventilation openings are
not blocked.

Card slots

None

Connectors

Twenty console ports for modular RJ-45
connectors

One RJ-45 (10BaseT) network interface

Table 8