Rebooting the mgc, Loadware upgrade – Nortel Networks 1000E User Manual

Page 149

Advertising
background image

Installing software on the CS 1000E

Page 149 of 466

Communication Server 1000E

Installation and Commissioning

Rebooting the MGC

The MGC reboots and registers with the Call Server.

Found device : INTEL 82365SL

Engcode:NTDW60BA REL 08

ELAN mac address is:00:13:65:ff:ee:ed

TLAN mac address is:00:13:65:ff:ee:ec

RESET reason: Hard Reset.

Daughter board 1:NTDW62AA R02 00:13:65:ff:f8:fd.

Daughter board 2:NOT INS

VxWorks System Boot

Copyright 1984-2005 Wind River Systems, Inc.

CPU: Chagall

Version: VxWorks5.5.1

Bootcode version: MGCBAA20

auto-booting...

Loading MSP from CF...1375736

Booting ARM0 (MSP) at 0x00000100 ...

Loading CSP from CF...6643712 + 5849088

Booting ARM1 (CSP) at 0x80010000 ...

Found device : INTEL 82365SL

Loading symbol table from /p/mainos.sym ...done

Loadware upgrade

If the MGC loadware is out of date (compared to the loadware on the Call
Server), an upgrade of the loadware occurs based on the Centralized Upgrade
setting defined during the software install and the values set in overlay 143.
The default values are set so that the upgrade starts automatically once
registration is achieved with the Call Server.

There are six pieces of loadware that are updated on the MGC. These updates
are downloaded from the Call Server.

Advertising