Installing a Signaling Server

Page 177 of 466

Communication Server 1000E

Installation and Commissioning

Installing the CP PM Signaling Server hardware

The Nortel CP PM server is a circuit card, and thus is not mounted in a rack.
This section contains instructions for installing a Nortel CP PM Signaling
Server in a CS 1000E and a CS 1000M system.

Made sure the area meets all environmental requirements?

Checked for all power requirements?

Checked for correct grounding facilities?

Obtained the following:

•

screwdrivers

•

an ECOS 1023 POW-R-MATE or similar type of multimeter

•

appropriate cable terminating tools

•

a computer (maintenance terminal) to connect directly to the Signaling Server, with:

—

teletype terminal (ANSI-W emulation, serial port, 9600 bps)

—

a web browser for Element Manager (configure cache settings to check for new
web pages

—

every time the browser is invoked, and to empty the cache when the browser is
closed)

Prepared the network data as suggested in Converging the Data Network with VoIP
(NN43001-260), Communication Server 1000E: Planning and Engineering
(NN43041-220) or Communication Server 1000M and Meridian 1 Large System
Planning and Engineering
(NN43021-220), as appropriate for your CS 1000 system?

Read all safety instructions in Communication Server 1000E: Installation and
Commissioning
(NN43041-310) or Communication Server 1000M and Meridian 1 Large
System Installation and Configuration
(NN43021-310), as appropriate for your CS 1000
system?

Table 14
Readiness checklist (Part 2 of 2)

Have you: