Connecting a trunk to a pftu, Procedure 108 connecting a trunk to a pftu, Procedure 108: "connecting a trunk to a pftu" on – Nortel Networks 1000E User Manual

Page 448

Advertising
background image

Page 448 of 466

Installing and cross-connecting a Power Fail Transfer Unit

NN43041-310

Standard 01.11

October 2008

End of Procedure

Connecting a trunk to a PFTU

Follow Procedure 108 to connect a Trunk to a PFTU.

Procedure 108
Connecting a Trunk to a PFTU

1

Locate the PFTU terminal blocks at the cross-connect terminal.

2

Cross-connect the first pair of the assigned PFTU to the telephone.

See Table 61 on

page 449

for PFTU connections.

3

Cross-connect the second pair of the PFTU to the TN assigned to the
telephone.

4

Cross-connect the third pair of the PFTU to the Central Office trunk.

5

Cross-connect the third pair of the PFTU to the TN assigned to the trunk.

PFT 5

21T

21R

V-BL

BL-V

Telephone

22T

22R

V-O

O-V

Telephone Line card

23T

23R

V-G

G-V

Central Office Trunk

24T

24R

V-BR

BR-V

Trunk Line card

Table 60
Power Fail Transfer Unit connections (Part 3 of 3)

QUA6 J1 Cable

Function

Pair

Color

Connects to:

Advertising