Nortel Networks 1000E User Manual

Page 183

Advertising
background image

Installing a Signaling Server

Page 183 of 466

Communication Server 1000E

Installation and Commissioning

5

Set the COM port on the maintenance terminal as follows:

Terminal type: VT100

Speed: 9 600

Data bits: 8

Parity: none

Stop bits: 1

Flow control: none

Note: The CP PM Signaling Server is shipped with the Admin Serial port
set to 9600 Bit/s. Other available speeds are 19 200, 38 400, and 115 200
Bits. You can change the port speed using the maintenance terminal. To
verify or change the baud rate on a Nortel CP PM Signaling Server, see
Signaling Server: Installation and Commissioning (NN43001-312).

6

Configure the Signaling Server maintenance terminal. Refer to Signaling
Server: Installation and Commissioning
(NN43001-312).

End of Procedure

Complete Procedure 39 to connect a Nortel CP PM Signaling Server (model
NTDW61BAE5) to the ELAN and TLAN subnets of a CS 1000E system.

Procedure 39
Connecting a CP PM Signaling Server to the ELAN and TLAN subnets of
a CS 1000E system

1

Connect the Signaling Server to the ELAN subnet.

if the Call Server is not connected to the Media Gateway Controller
(MGC) CE port

Insert the end of one of the 25-cm RJ-45 CAT5 Ethernet cables
shipped with the server (NTDU0606E6) into the ELAN network
interface port (ELAN port) on the faceplate of the server

insert the other end of the 25-cm RJ-45 CAT5 Ethernet cable
into the MGC ELAN Ethernet port

if the Call Server is connected to the CE port

Advertising