System components

Page 51 of 466

Communication Server 1000E

Installation and Commissioning

The TTY Settings are:

•

Baud Rate: 9600

•

Data bit: 8

•

Stop bit: 1

•

Parity: None

•

Flow Control: None

CP PM Call Server Switch Settings

The CP PM Call Server switch S5 must be set to position 1 to indicate that a
CF card is used for the FMD.

The CP-PM Signaling Server switch S5 must be set to position 2 to indicate
that a hard disk is used for the FMD.

CP PM Call Server software

The CP PM Call Server software features the following enhancements for
CS 1000 Release 5.0:

•

software is large-system based

•

uses the same machine type (711) as CP PII and CP PIV

•

new system type (4021)

•

new High Availability package (410)

•

new menus for setting the Side, Loop and Shelf information. The Loop
and Shelf refer to the IPMG Loop and Shelf where the CP PM CS is
located.