Installing and cross-connecting a Power Fail Transfer Unit

NN43041-310

Standard 01.11

October 2008

The following procedures are provided in this chapter:

1

Procedure 106: "Installing and connecting a QUA6 PFTU" on

page 438

2

Procedure 107: "Connecting an analog (500/2500-type) telephone to a
PFTU" on

page 446

3

Procedure 108: "Connecting a Trunk to a PFTU" on

page 448

Installing and connecting a QUA6 PFTU

Follow Procedure 106 to install and connect a QUA6 PFTU. Refer to the
equipment layout plan for the location of the PFTU.

Note: The QUA6 PFTU operates with loop-start and ground-start
Central Office trunks. With ground start trunks, the associated telephone
set must have a ground start button.

Procedure 106
Installing and connecting a QUA6 PFTU

1

Install the PFTU on the wall near the system cross-connect terminal.

Fasten the PFTU in position

with four screws.

2

Install an NE-A25B-type 25-pair cable from connector J1 on the faceplate
of the PFTU to its assigned location at the cross-connect terminal.

3

Label the pairs of the J1 cable on the cross-connect terminal block as
shown in Figure 178 on

page 438

.

Figure 178
J1 cable labels

Control

PFT1

PFT2

PFT3

PFT4

PFT5

PFT1

Power

Pairs

1 to 4

Pairs

1 to 4

Pairs

1 to 4

Pairs

1 to 4

Pairs

1 to 4

Pairs

1 to 4

Pairs

1 to 4

Label the pairs on the terminal block as shown. If using
BIX blocks, attach the appropriate designation strip.