Procedure 107
Connecting an analog (500/2500-type) telephone to a PFTU

1

Locate the telephone terminations on the cross-connect terminal.

2

Connect one end of the cross-connect wire to the leads of the telephone.

3

Locate the PFTU connections (unit PFTU 1 through PFTU 5) assigned to
this telephone at the cross-connect terminal. See Table 60 on

page 446

.

4

Connect the other end of the cross-connect wire to the pair assigned to
the telephone on the PFTU.

5

Connect a second cross-connect wire to the pair assigned to the Line card
on the PFTU.

6

Locate the Line card terminations on the cross-connect terminal.

7

Connect the other end of the cross-connect wire to the assigned TN
terminal block.

Table 60
Power Fail Transfer Unit connections (Part 1 of 3)

QUA6 J1 Cable

Function

Pair

Color

Connects to:

PFT 1

5T

5R

W-S
S-W

Telephone

6T

6R

R-BL
BL-R

Telephone Line card

7T

7R

R-O
O-R

Central Office Trunk

8T

8R

R-G
G-R

Trunk Line card