Installing and cross-connecting a Power Fail Transfer Unit
Page 443 of 466
Communication Server 1000E
Installation and Commissioning
Installing and connecting a third-party PFTU
Follow the equipment manufacturer’s instructions for installing the PFTU.
Use the information in Table 59 to connect a third-party PFTU.
Note 1: Refer to Figure 180 on
to see where the Auxiliary
cable connects to the CS 1000E system.
Note 2: If power is removed from the QUA6, a transfer of the PFTU can
occur.
Table 59
PFTU control lead signals
Lead State
NTAK1104 AUX
cable lead
When PFTU is in
non-transferred state
When PFTU is in
transferred state
BRTN
GROUND
GROUND
BRTN
GROUND
GROUND
-48V AUX
-48V DC (250 mA max.)
-48V DC (250 mA max.)
PFTS
OPEN
GROUND