Guidelines for component placement in a rack – Nortel Networks 1000E User Manual

Page 83

Advertising
background image

Rack-mounting the components

Page 83 of 466

Communication Server 1000E

Installation and Commissioning

Guidelines for component placement in a rack

When installing equipment, the Layer two switches should be in a central
location to allow for easy access of all LAN cabling. The Media Gateways
and Media Gateway Expanders must be mounted together vertically, and they
must be powered from the same power rail. Typical vertical power bars in
equipment racks are rated at 15/20 amps @ 120 volts. Ensure that the
equipment load does not exceed the power bar rating. Refer to
Communication Server 1000E: Planning and Engineering (NN43041-220)
for information on power consumption. Do not place redundant equipment on
the same electrical circuit.

There are no thermal concerns about equipment placement.

Note 1: Leave wall space for the cross-connect terminal.

Note 2: Position the rack so that you have access to both the front and
rear.

Media Gateway Expander

without cards

with 4 cards

26

30

12

13.5

BayStack 470 Switch

14.7

6.7

BayStack 460 Power over Ethernet Switch

12.76

5.8

MRV Terminal Server

11

5

Table 11
Weight of CS 1000E system components (Part 2 of 2)

Component

Lbs

Kg

Advertising