Connecting an hp dl320-g4 signaling server – Nortel Networks 1000E User Manual

Page 187

Advertising
background image

Installing a Signaling Server

Page 187 of 466

Communication Server 1000E

Installation and Commissioning

5

Set the baud rate for the serial port on the Signaling Server to 9 600 b/ps.
See Signaling Server: Installation and Commissioning (NN43001-312).

Note: The IBM X306m Signaling Server ships with the serial port set to
9600 b/ps.

6

Configure the connected maintenance terminal. See Signaling Server:
Installation and Commissioning
(NN43001-312).

7

Press the Power switch.

Note: Refer to the Signaling Server Product Guide on the CD-ROM
shipped with the IBM X306m Signaling Server for additional operating
information.

End of Procedure

Connecting an HP DL320-G4 Signaling Server

In geographic regions that are susceptible to electrical storms, Nortel
recommends that you plug the HP DL320-G4 Signaling Server into an AC
surge suppressor.

Figure 60 shows the rear view of the HP DL320-G4 Signaling Server.

Figure 60
HP DL320-G4 Signaling Server (rear view)