Cs 1000e cp pm call server com port connections – Nortel Networks 1000E User Manual

Page 281

Advertising
background image

Configuring a terminal and SDI ports

Page 281 of 466

Communication Server 1000E

Installation and Commissioning

Figure 121
VT220 setup values

CS 1000E CP PM Call Server COM Port connections

There are 2 serial ports on the CP PM Call Server, Port 0 and Port 1. They are
accessed through a special cable that attaches to the MDF port at the back of
the cabinet. Both ports are standard RS232 DTE ports. The supported TTY
settings for both ports are:

Baud rate - 9600

Data bit - 8

Stop bit - 1

Global Set-Up
On Line

Comm1=RS232

Sessions on Comm1

70Hz

CRT Saver

Printer Shared

Display Set-Up
80 Columns

Light Text, Dark Screen

Interpret Controls

Cursor

Auto Wrap

Block Style Cursor

Jump Scroll

General Set-up
VT200 Mode, 7-bit Controls

Application Keypad

User Defined Keys Unlocked

Normal Cursor Keys

User Features Unlocked

No New Line

Multinational

Communications Set-Up
Transmit=2400

No Local Echo

Receive=Transmit

Data Leads Only

Xoff at 64

Disconnect, 2 s Delay

8bits, No Parity

Limited Transmit

1 Stop Bit

Printer Set-Up
Speed=9600
Normal Print Mode

Print Full Page

8bits, No Parity,

Print National Only

1 Stop bit

No Terminator

Keyboard Set-up
Typewriter Keys

Warning Bell

Caps Lock

Break

Auto Repeat

Answerback=

Keyclick High

Not Concealed

Margin Bell

Tab Set-Up Screen
Leave this screen at the default values