Installing software on the CS 1000E

Page 145 of 466

Communication Server 1000E

Installation and Commissioning

The MGC Shells can be accessed using the following commands:

<CTRL>O<CTRL>A<CTRL>M,

(provide OAM username and

password to access OAM shell)

<CTRL>L<CTRL>D<CTRL>B,

(provide LDB username and

password to access LDB)

1

Enter network IP information at the MGC setup menu:

Please define the data networking parameters for this

MG 1000E now.

Hostname: MGC_N313 (optional)

ELAN IP: 0.0.0.0 192.168.3.33

ELAN subnet mask: 0.0.0.0 255.255.255.0

ELAN gateway IP: 192.168.3.1

TLAN IP: 0.0.0.0 192.168.19.33

TLAN subnet mask: 0.0.0.0 255.255.255.0

TLAN gateway IP : 192.168.19.1

Primary CS Hostname: CS1000E_N313 (optional)

Primary CS IP: 192.168.3.32

Leading Secondary CS Hostname:<enter>

Leading Secondary CS IP: 0.0.0.0

Secondary CS Hostname: <enter>

Secondary CS IP: 0.0.0.0