JOB CONTROL TASKS

XEROX DOCUPRINT 180 LPS OPERATOR GUIDE

5-9

Figure 5-5.

Sample test form

Step 4.

If further adjustments are needed, repeat steps 2 and 3 until you are
satisfied with the results.

There is another method used to set alignment with the system-
generated test pattern. Enter the ALIGN command with the new
values, followed immediately (no spaces) by, TEST (for example,
ALIGN 3,8,TEST). This command sets the new values and
automatically generates a single test form sample for your
evaluation. The new values are printed near the top of the form.

The ALIGN, TEST command may be used any time you wish to
generate a sample test form with the current values printed on it.
(You could use this command in step 1, instead of the basic ALIGN
command.)

Note:

Remember to restore the printer to its original values. Enter

ALIGN and the original values, whatever they were at the beginning.
Refer to step 1.