SYSTEM CONTROL TASKS

XEROX DOCUPRINT 180 LPS OPERATOR GUIDE

4-13

Attention Light/Alarm task

through command line

To enable the Attention light, enter the following command:

ATTENTION LIGHT ENABLE [STEADY

|

FLASHING]

Table 4-1 lists each parameter and its description.

To disable the Attention light, enter the following command:

ATTENTION LIGHT DISABLE [STEADY

|

FLASHING]

Table 4-2 lists each parameter and its description.

To enable the alarm, enter the following command:

ATTENTION ALARM ENABLE {0-10}

0-10 Sets the tone volume for the alarm. 0 is softest, 10 is loudest
volume.

To disable the alarm, enter the following command:

ATTENTION ALARM DISABLE

Table 4-1.

ATTENTION LIGHT ENABLE command parameters
and descriptions

Parameter

Description

STEADY

Enables only the steady mode of the Attention
light.

FLASHING

Enables only the flashing mode of the Attention
light.

Table 4-2.

ATTENTION LIGHT DISABLE command
parameters and descriptions

Parameter

Description

STEADY

Disables only the steady mode of the Attention
light.

FLASHING

Disables only the flashing mode of the Attention
light.